Topic outline

1
Hydraulic Schematics
Show only topic 1
2
Pumps
Show only topic 2
3
Manifold Blocks
Show only topic 3
4
Troubleshooting
  • If Press Will Not Close:

    1) If none of the Actuators are working see " Power Unit Checks"

    2) Check Permissives: Shear Up, Loader Down, Die Slide in, Container Tilt, Charger Down, etc.

    3) Solenoids (?), (?), (?), must be energized.

    4) Check Side Cylinders Cap End pressure, should read (???) psi.

    5) Check Side Cylinders Rod End Pressure, should read (???) psi.

    6) Check That Prefill Valve is Open.

    7) Check for mechanical Binding

  • Press Will Not Extrude:

    1) If system Pressure is too low see "Power Unit Checks"

    2) Check Permissives: Ram against container, Shear Up, Loader Down, Die-Slide in, Container Tilt, Charger Down, etc.

    3) Solenoids (?), (?) must be energized.

    4) Check that Prefill is closed

    5) Check Side cylinders and related valves for bypass (heat)

    6) Check for cold Billet

  • Press Closes Slowly:

    Press Will not Open:

    Press Opens Slowly:

    Container will not Close:

    Container will not Open:

    Container will not Seal:

    Power Unit Checks:

Show only topic 4

4KT.jpg

Press_Closing_1.jpg